MODEL G4013
20 GALLON PARTS
WASHER
INSTRUCTIONS
If you need help with your new item, call our Tech
Support at: (570) 546-9663.
Damage to your eyes, lungs, and skin could
result from using this item without proper
protective gear, such as face shield, a respi-
rator, and rubber gloves.
Work
Pump Box
Basket
Work
Shelf
Specifications
Overall Size ...................... 30" L x 21" W x 35" H
Tub Depth ............................................. 10" Deep
Maximum Liquid Level......10-Gallons or 5" Deep
Minimum Liquid Level........ 6-Gallons or 3" Deep
Nozzle Diameter....................................... 5.5mm
Pump Motor.......................110V, 0.7 Amp, 60 Hz
Pump Output .......................................... 50 GPH
Net Weight.................................................57 lbs.
Tub
Shelf
Drain
Plug
Inventory (figure 1)
Qty
Work Basket ...................................................... 1
Pump Box.......................................................... 1
Work Shelf......................................................... 1
Tub ................................................................... 1
Shelf .................................................................. 1
Legs................................................................... 4
Bolt Bag............................................................. 1
—Phillips Head Screws M6-1 X 12 (Legs)25
—Hex Nuts M6-1 (Legs)........................... 25
—Lock Washers 6mm (Legs)................... 25
—Phillips Head Screws M4-.7 X 10
Legs
figure 1. Assembly diagram.
Power Supply Circuit Requirements
Only connect this parts washer to a power supply
circuit that is protected with a GFCi (Ground Fault
Circuit interrupt) device. If you are unsure about
the wiring codes in your area or you plan to
connect your machine to a shared circuit, con-
sult a qualified electrician.
(Switch Box) ............................................ 2
—Hex Nuts M4-.7 (Switch Box).................. 2
—Lock Washers 4mm (Switch Box)........... 2
Power Supply Voltage ...........................110 Volts
Minimum Circuit Size............................. 10 Amps
COPyriGHT © AUGUST, 2009 By GrizzLy iNDUSTriAL, iNC.
WARNING: NO PORTION Of THIS MANUAL MAy bE REPRODUCED IN ANy SHAPE
OR fORM WITHOUT THE WRITTEN APPROvAL Of GRIzzLy INDUSTRIAL, INC.
#Cr12088 PriNTeD iN CHiNA
(MSDS) information, which often can be found on
the internet also. it is your responsibility to select
a safe solution.
Power Connection Device
This machine comes with a 5-15 style plug. For
improved electrical safety against fire or electrical
shock, only connect this power cord to a GFCi
protected circuit or receptacle (figure 3).
Never run this parts washer if the tank is empty
or if the filter is clogged. if you do, pump damage
will occur.
Grounding Prong is
Longest of the Three
Prongs
Operation
Use the switch to turn on the pump and spray
fluid from the nozzle. Parts may also be dunked or
soaked in the solvent and cleaned with a brush.
Current
Carrying Prongs
Grounded
GFCI Outlet
bIOLOGICAL and POISON
figure 3. Typical 5-15 plug and GFCi receptacle.
HAzARD!
Extension Cords
We do not recommend using extension cords, but
if you find it absolutely necessary:
•
•
•
Use at least a 16 gauge cord that does not
exceed 50 feet in length!
The extension cord must have a ground wire
and plug pin.
This parts washer is designed to store
cleaning solutions. During storage, some
liquids can grow dangerous microbes, or
due to the collection of toxic metal and
contaminants from the items being washed,
the fluid can become a very poisonous
solution to humans and animals.
A qualified electrician MUST size cords over
50 feet long to prevent pump motor damage.
Selecting a Solvent
This heavy-duty welded steel parts washer has
a 20 gallon work-space volume, but is designed
to hold a maximum of 10 gallons of liquid. Do not
overfill. Not every cleaning solution is safe to use
in your parts washer. NeVer USe GASOLiNe,
KerOSeNe, FUeLS, STriPPerS, Or ACiDS
OF ANy KiND iN THiS PArTS WASHer.
USE the correct personal protection
equipmentwhenhandlingsharpworkpieces
to prevent cuts, infections, and poisoning.
fOLLOW OSHA, EPA, and the fluid
manufacturer's requirements to properly
dispose of cleaning liquids when it becomes
time to change the liquid.
We recommend non-flammable cleaning solutions
with a PH between 6 and 8, but due to the chang-
ing formulas of cleaning solutions and changing
laws and regulations, we cannot name a specific
solution for you.
USE this parts washer with caution and
respect. Always consider safety first, as it
applies to your individual working condi-
tions. No list of safety guidelines can be
complete—every shop environment is dif-
ferent. failure to follow safety guidelines
could result in serious personal injury or
death.
Some solutions can be highly flammable and may
damage pump and motor seals, and others can
react with what you may be cleaning and produce
harmful fumes.
if you are in doubt about any aspect of your
selected solution, contact the solution manufac-
turer or refer to its Materials Safety Data Sheet
-3-
Model G4013 20-Gallon Parts Washer
•
•
MODIfICATIONS. Using aftermarket parts or
modifying the wiring beyond what is shown
in the diagram may lead to unpredictable
results, including serious injury or fire.
Wiring Safety
These pages are current at the time of printing.
However, in the spirit of improvement, we may
make changes to the electrical systems of future
machines. Study this section carefully. if there are
differences between your machine and what is
shown in this section, call Technical Support at
(570) 546-9663 for assistance BeFOre making
any changes to the wiring on your machine.
MOTOR WIRING. The motor wiring shown
in these diagrams is current at the time of
printing, but it may not match your machine.
Always use the wiring diagram inside the
motor junction box.
•
SHOCK HAzARD. Working on wiring that
is connected to a power source is extremely
dangerous. Touching electrified parts will
result in personal injury including but not lim-
ited to severe burns, electrocution, or death.
Disconnect the power from the machine
before servicing electrical components!
•
CAPACITORS/INvERTERS. Some capaci-
tors and power inverters store an electrical
charge for up to 10 minutes after being dis-
connected from the power source. To reduce
the risk of being shocked, wait at least this
long before working on capacitors.
•
•
CIRCUIT REQUIREMENTS. you MUST fol-
low the requirements at the beginning of this
manual when connecting your machine to a
power source.
•
QUALIfIED ELECTRICIAN. Due to the inher-
ent hazards of electricity, only a qualified
electrician should perform wiring tasks on this
machine. if you are not a qualified electrician,
get help from one before attempting any kind
of wiring job.
EXPERIENCING DIffICULTIES. if you are
experiencing difficulties understanding the
information included in this section, contact
our Technical Support at (570) 546-9663.
•
•
WIRE CONNECTIONS. All connections must
be tight to prevent wires from loosening
during machine operation. Double-check all
wires disconnected or connected during any
wiring task to ensure tight connections.
WIRE/COMPONENT DAMAGE. Damaged
wires or components increase the risk of seri-
ous personal injury, fire, or machine damage.
if you notice that any wires or components
are damaged while performing a wiring task,
replace those wires or components before
completing the task.
-4-
Model G4013 20-Gallon Parts Washer
Wiring Diagram
GFCI
Only connect this parts washer to a
properly grounded GFCI (Ground Fault
Circuit Interrupt) receptacle. Test the
GFCI receptacle operation according to
switch at the manufacturers
recommended intervals.
SWITCH
(viewed from behind)
110V
Pump Motor
Neutral
Hot
Ground
Ground
110 VAC
5-15 Plug
The photos and diagrams
included in this section are
best viewed in color. You
can view these pages in
-5-
Model G4013 20-Gallon Parts Washer
Parts
20A
24
1
2
3
49
3
18
19
17
15
40
4
16
49
6
20V2
17
21
4
23
7
18
25
30
28
29
15
16
17
15
8
9
12
10
11
14
26A
32
31
48
13
REF PART #
DESCRIPTION
COVER
REF PART #
19 P4013019
20V2 P4013020V2 PUMP HOUSING V2.04.04
DESCRIPTION
POWER CORD W/PLUG
1
P4013001
P4013002
P4013003
P4013004
P4013006
P4013007
PLW03M
PN01M
2
WORK BASKET
3
COTTER PIN 1.5 X 16
CLEVIS PIN 5 X 30
WORK SHELF
20A
21
23
24
25
26A
28
29
30
31
32
40
48
49
P4013020A
P4013021
P4013023
P4013024
P4013025
P4013026A
P4013028
P4013029
P4013030
PORP015
P4013032
P4013040
PORP021
PW02M
COMPLETE PUMP BOX W/ELECTRICAL
SCREEN
4
6
SWITCH BOX W/SWITCH
FLEX HOSE W/NOZZLE
MOUNTING PLATE
PUMP ASSEMBLY V2.07.04
FILTER COVER
7
TUB
8
LOCK WASHER 6MM
HEX NUT M6-1
RUBBER WASHER
DRAIN PLUG
9
10
11
12
13
14
15
16
17
18
P4013010
P4013011
P4013012
P4013013
PS14M
PUMP BOX COVER
ELBOW
SHELF
LEG
O-RING 14.8 X 2.4 P15
SPIGOT
PHLP HD SCR M6-1 X 12
HEX NUT M4-.7
FLAT WASHER 4MM
PHLP HD SCR M4-.7 X 10
STRAIN RELIEF
PN04M
FIRE FUSE LINK LEVER
O-RING 20.8 X 2.4 P21
FLAT WASHER 5MM
PW05M
PS38M
P4013018
-6-
Model G4013 20-Gallon Parts Washer
Label Placement
104
103
101
102
108
105
107
106
REF PART #
DESCRIPTION
REF PART #
DESCRIPTION
101
102
103
104
P4013101
NO SMOKING LABEL
105
106
107
108
P4013105
GFCI WARNING LABEL
P4013102
P4013103
SOLVENT TYPE WARNING LABEL
FACE SHIELD WARNING LABEL
PLABEL-12B READ MANUAL LABEL
P4013107
P4013108
DATA LABEL
PLABEL-14B ELECTRICITY WARNING LABEL
RUBBER GLOVES WARNING LABEL