HP NetServer LPr
with
XP256 (Fibre Channel or SCSI)
Cluster Configuration Guide
08 February, 2000
Introduction
This document defines the supported HP NetServer LPr configurations with the XP256 and Microsoft
Cluster Server. These configurations minimize single points of failure (SPOF), provide maximum
availability, and have been certified by Hewlett-Packard or Microsoft. This guide is prescriptive; it
describes the configurations supported by HP. Any deviance to these configurations can result in an
inoperative cluster or an operating cluster with degraded performance, hidden SPOFs, etc., and therefore
will not be supported by HP.
What’s Defined in a Cluster
Cluster
SPUs
Local and Shared Storage
Intra-cluster and Client LANs
Shared Storage Cabling
Cluster
Type of SPUs
HP NetServer LPr.
Each node must be the same model SPU, but may have different clocks
speeds, main memory sizes, cache sizes, and number of CPUs (2, 3, or 4).
Number of nodes
Shared Storage
LANs:
2
XP256 with FC or SCSI connections. See Shared Storage below.
Client LAN
Any NIC that is HP and Microsoft approved. See Client LAN below.
HP D5013A with crossover cable. See Intra-cluster LAN below.
Intra-cluster
(Heartbeat) LAN
Power source
Direct from power mains, power conditioner or uninterruptible power
supply (UPS) using any power conditioner or UPS.
System software:
Navigator version
Operating System
Service pack
L.16.05 or later
Microsoft Windows NT Server 4.0, Enterprise Edition or later
SP5 or later
1
XP256 Disk Array
Microcode
43.12 (Direct Connect)
44.14 (All Configs)
Open Volume Sizes
(LDEVs)
VOL TYPE SIZE MAX EXTENDED LUN SIZE
Open 3*n
Open 8*n
Open 9*n
2.4G
7.2G
7.3G
2.4G x 36= 86.4G
7.2G x 36= 259.2G (where “n”= 1-36)
7.3G x 36= 262.8G
Disk Capacities
RAID levels
15GB, 36GB, 47GB
1 & 5
Max number of LUNs
Port Host Modes
8 shared LUNS per cluster
08 (Fibre)
00 (SCSI)
Port Fabric Modes
Using SVP (in MODIFY mode), go to SCSI PATH/FIBRE/TOPOLOGY.
Turn FABRIC and LOOP to ON.
SCSI Cables
2.5 meter
Either of the 2 HP SCSI cables from the following list:
C2924A 68 pin HD Male to 68 pin HD Male
C2925A 68 pin HD Male to 68 pin HD Male
10 meter
FC Cables
2 meter
Any 2 HP shortwave cables from the following list:
A3583A
A3531A
A3735A
A3736A
16 meter
50 meter
100 meter
Shared Storage Configurations
Point to Point
Direct Fibre Channel or SCSI connections. Each SCSI Port on XP256 has
two available connection points (internal logical Y connection); one is
cabled to Server #1 of the cluster, the other to Server #2 (see diag 1, page
5).
Fibre Channel Hub
Model
A3724A HP-10 port Short Wave FC Hub
A4839A HP-10 port Long Wave FC Hub
1 per SPOF cluster
No. of hubs
No. of clusters/hub
1 cluster on 1 hub
Fibre Channel Switch
Model
A5223A (non-cascading) or A5224B (cascading)
A5624A/AZ Brocade 2800 FC Switch
Fabric Support
No. of switches
FL Port (Turn EPL to OFF for desired ports)
1 per SPOF cluster, 2 per SPOFless cluster
No. of clusters/switch SPOF: 1, SPOFless: 4 cluster nodes (See pg.5)
3
LANs
Intra-cluster (Heartbeat) LAN
Client LAN
LAN connection
HP D5954A crossover cable or
equivalent
Any LAN
The intra-cluster LAN may only be
used for cluster node communication
via a crossover cable. It may not be
used for client communication.
NIC:
Model
HP D5013A (10/100TX PCI)
3.27.00.0001 or later
Any that is on both the HP Tested
Products List and the Microsoft
Hardware Compatibility List.
Driver
Any driver
NOTE If the NIC used is the
same as the Intra-cluster LAN,
then the Client LAN must use the
same driver as the Intra-cluster
LAN.
No. of NICs
SPU I\O slot
1
1 minimum
P2
P4
4
Shared Storage Cabling
This part of the guide defines the allowable cabling configurations for clusters using the HP NetServer
LPr and the XP256. Only these cabling configurations and cables are supported.
DIAGRAMS SHOWING THE SUPPORTED CONFIGURATIONS
LPr
LPr
LPr
LPr
Hub/Switch
XP256
XP256
LPr
LPr
1a
LPr
1b
LPr
2b
LPr
LPr
2a
Switch
Switch
XP256
LPr
4a
LPr
3a
LPr
3b
LPr
4b
XP256
5
|