Honeywell Home Security System 400 User Manual

FBII Security System  
®
®
OMNI 400/OMNI 600  
®
®
OMNI 624/OMNI 848  
User Guide  
N9939V5 4/04 Rev. A  
 
Quick Reference  
TO ARM THE SYSTEM  
1. Check to make sure the system is ready. (The Green READY light is lit.)  
2. Enter your 4-digit (or 6-digit) user code.  
The ARMED/ light will light.  
3. Exit through a door designated by your installer as an exit/entry door.  
NOTE: If you DO NOT EXIT during the exit time and your system installer has  
programmed your system for Auto-Stay, the system will arm in the Auto-Stay  
mode.  
TO DISARM THE SYSTEM  
1. Enter through a door designated by your installer as an exit/entry door.  
2. Enter your 4-digit (or 6-digit) user code.  
The ARMED/ light will go out.  
TO ARM THE SYSTEM AND STAY INSIDE  
1. Check to make sure the system is ready. (The Green READY light is lit.)  
STAY  
2. Press  
/
.
3. Enter your 4-digit (or 6-digit) user code.  
The ARMED/ light and STAY/  
light will both light.  
REMEMBER: Unless the Quick Exit feature is enabled, you must disarm the  
system if you want to open the door or leave the premises after the exit time has  
passed.  
TO ARM THE SYSTEM IN INSTANT MODE, AND STAY INSIDE  
1. Check to make sure the system is ready. (The Green READY light is lit.)  
INSTANT  
2. Press  
3. Press  
/
/
.
.
STAY  
4. Enter your 4-digit (or 6-digit) user code.  
The ARMED/ light, the INSTANT/  
light, and the STAY/  
light will all be  
lit.  
TO RESET SMOKE DETECTOR  
1. Enter your 4-digit (or 6-digit) user code twice.  
- 3 -  
 
Quick Reference (cont)  
The following table lists the “Quick Commands” available with this control.  
Key  
# 1  
Description  
Quick Arm – if system is ready  
Keypads Comments  
All keypads Allows you to arm the system without requiring your  
user code. User code is always needed to disarm  
the system.  
Force Arm – bypasses faulted  
zones  
All keypads Allows you to arm the system even if some zones  
are faulted. These zones will be automatically  
bypassed and will be unprotected.  
# 2  
BYPASS  
Quick Bypass  
All keypads If not enabled, requires user code with authority 1,  
2, or 3.  
nn (zone no.)  
# 3  
Set Time and Date  
Zone Directory  
All keypads May require user code.  
LCD* only  
Lists each zone with its descriptors. Mode  
terminates after last enabled zone.  
# 4  
Quick Help (OMNI624/848 only)  
LCD* only  
Provides a listing of all quick commands available in  
the system.  
# 50  
Show Time and Date  
Show Auto Arm Time  
User Event Log View  
Set Auto Arm Time of Current  
Partition (OMNI624/848) or  
System (OMNI400/600)  
LCD* only  
LCD* only  
LCD* only  
May also require code.  
May also require code.  
Also needs user code with authority level 1 or 2.  
# 51  
# 52  
# 53  
# 54  
All keypads By partition (OMNI624/848) or system  
(OMNI400/600), may also require code.  
Display Firmware Version  
LCD* only  
Displays panel’s revision.  
# 55  
# 56  
Display Key Fob Low Batteries  
(OMNI624/848 only)  
Door Strike  
All keypads Wireless Key Fob battery test.  
All keypads Activate doorstrike or trigger. May require certain  
user code.  
All keypads For keypad partition (OMNI624/848) or system  
(OMNI400/600), only LCD* shows phone number.  
All keypads LCD* displays current state first, then offers to  
toggle. All others just toggle the state.  
# 57  
# 58  
# 6  
Change/View Pager Number  
Display/Toggle Chime Mode  
Assign User to Other Partition  
or to Activate Paging  
All keypads Need user auth. of 1 or 2. Digit 4 (P) enables user  
to page.  
# 7  
(OMNI624/848 only)  
Paging must be enabled and turned on.  
User Page Toggle  
All keypads Toggles if users should send page for  
Open/Close by partition (OMNI624/848) or by  
system (OMNI400/600).  
# 8  
User On-line  
All keypads Connects to downloader while on line, disconnects  
home phone.  
All keypads LCD* displays current enables, 1, 2, 3 – P = 4  
NOTE: An entry of 3 is available for the OMNI848  
only  
# 9  
# 0  
Multi-Partition (OMNI624/848  
only)  
* 2-line alpha display  
- 4 -  
 
Quick Reference (Cont’d)  
The following table provides a summary listing of LED indications when using a LED keypad.  
SLOW PULSE  
(approx. 600mS ON  
600mS OFF)  
FAST BLINK  
(approx. 150mS ON  
150mS OFF)  
SLOW BLINK  
(approx. 100mS ON  
900mS OFF)  
INDICATOR  
ON  
Armed  
Comm. Fail  
Alarm  
ARM /  
AC good  
Ready  
Syst Batt Trbl  
AC/LB /  
Program Mode  
Alarm memory  
READY /  
1
2
3
4
5
6
7
8
Zone Fault  
Zone Fault  
Zone Fault  
Zone Fault  
Zone Fault  
Zone Fault  
Zone Fault  
Zone Fault  
Stay Armed  
Zone Trouble  
Zone Trouble  
Zone Trouble  
Zone Trouble  
Zone Trouble  
Zone Trouble  
Zone Trouble  
Zone Trouble  
Zone Alarm  
Zone Alarm  
Zone Alarm  
Zone Alarm  
Zone Alarm  
Zone Alarm  
Zone Alarm  
Zone Alarm  
Zone Bypass  
Zone Bypass  
Zone Bypass  
Zone Bypass  
Zone Bypass  
Zone Bypass  
Zone Bypass  
Zone Bypass  
STAY /  
INST /  
Instant Armed  
Arm disabled  
Phone Fail  
TRBL /  
Bell Supr  
Zone Tamper  
SUPER /  
Other LED display combinations:  
Slow Pulse of ARM/ , AC/LB/  
, and READY/  
LEDs indicate the system is in Walk  
Test Mode.  
Fast Blink of Zone and SUPER /  
LEDs indicate a tamper condition for the blinking  
zone.  
- 5 -  
 
Introduction  
®
Congratulations on your decision to protect your home or business with the OMNI  
security system. You have chosen a reliable, state-of-the-art security system that is  
remarkably easy to operate. Your system has been professionally installed by your  
local Security Company whose representative can explain the specifics of your  
system.  
The keypad is the input and display device for your security system. Your Security  
Company representative will suggest the model most appropriate for your premises  
and your needs. There are three types of keypads that can be used with this system:  
LCD keypad (alpha display), Fixed-Word keypad (2-digit display), or LED keypad.  
Since your system may use any of these keypads, the displays of all keypads are  
described in this manual.  
The OMNI400, OMNI600, OMNI624, and OMNI848 are listed by Underwriters  
Laboratories for Household Fire and Burglary applications.  
Throughout this manual, the following conventions are used to represent the  
keystrokes required to perform the following functions.  
STAY  
/
/
/
/
Press Button labeled STAY or  
.
BYPASS  
Press Button labeled BYPASS or  
Press Button labeled INSTANT or  
Press Button labeled CODE or  
.
INSTANT  
CODE  
.
.
Enter 4-digit (or 6-digit) user code.  
Please keep your manual in a convenient location so you can refer to it if  
needed.  
- 6 -  
 
System Reference  
ZONE DESCRIPTIONS  
In the following table, enter a description of the area of protection for each zone.  
Example: Zone 1 Windows on North side of building.  
Zone 4 Main entrance to building.  
Zone  
1
2
3
4
5
6
7
8
Description  
Zone  
25*  
26*  
27*  
28*  
29*  
30*  
31*  
32*  
33*  
34*  
35*  
36*  
37*  
38*  
39*  
40*  
41*  
42*  
43*  
44*  
45*  
46*  
47*  
48*  
Description  
9*  
10*  
11*  
12*  
13*  
14*  
15*  
16*  
17*  
18*  
19*  
20*  
21*  
22*  
23*  
24*  
* Zones 9 through 48 are not used with the OMNI400.  
Zones 13 through 48 are not used with the OMNI600.  
Zones 25 through 48 are not used with the OMNI624.  
Entry time ________ Door __________ Exit time ________  
Entry time ________ Door __________  
Exit time is the same for all designated entry/exit doors.  
- 7 -  
 
System Reference (cont)  
SEND-HELP ALERT  
All keypads are equipped with emergency-pair keys. In order to activate  
the alert, both keys must be pressed at the same time. The type of keypad  
you have installed dictates which keys you press. Your installer will show you how  
to activate these emergency keys. The emergency keys used for all keypads are  
shown below.  
The following SEND - HELP ALERT is programmed into my system:  
KEYS  
DESCRIPTION  
&
&
&
#
7
1
9
3
NOTE: These key combinations may also be programmed for other system  
functions.  
PAGER ALERT  
If programmed, a button on a designated keyfob may also be used to send an alert  
message to a pager. Ask your installer if this was done.  
MONITORING STATION INFORMATION  
Account #  
Telephone #  
- 8 -  
 
System Reference (cont)  
USER CODE ASSIGNMENTS  
In the following table, enter the names of the individuals assigned to each user  
number.  
User  
1
2
3
4
5
6
7
8
Assigned To…  
User  
33*  
34*  
35*  
36*  
37*  
38*  
39*  
40*  
41*  
42*  
43*  
44*  
45*  
46*  
47*  
48*  
49*  
50*  
51*  
52*  
53*  
54*  
55*  
56*  
57*  
58*  
59*  
60*  
61*  
62*  
63*  
64*  
Assigned To…  
9
10  
11  
12  
13  
14  
15  
16*  
17*  
18*  
19*  
20*  
21*  
22*  
23*  
24*  
25*  
26*  
27*  
28*  
29*  
30*  
31*  
32*  
* User Codes 16 through 64 are not used with the OMNI400 or OMNI600.  
User Codes 33 through 64 are not used with the OMNI624.  
____ ____  
4-digit 6-digit  
USER CODE NOTE: User codes can be either 4 digits or 6 digits, depending on installer  
programming. Ask your installer what type of user codes (4 or 6 digits) are being used in  
your system. When performing system functions, you must use the appropriate 4- or 6-  
digit user codes.  
- 9 -  
 
Arming the System  
IS THE SYSTEM READY?  
You can arm and disarm the burglar portion of your security system. Before you  
can arm the system, it must be “ready.” If you have a protected door open, or  
someone is moving in view of a motion detector, the system will not display the  
READY” message.  
The system is ready if the READY/  
light is lit and the display shows:  
LCD Keypad:  
Fixed-Word Keypad:  
READY/ LED lit  
LED Keypad:  
READY/ LED lit  
SYSTEM READY  
NOTE: If programmed by your installer, you may arm the system if a delay or  
interior zone is faulted. However, faulted zones must be restored before your exit  
time expires or an alarm or zone bypass will result. Ask your installer if your  
system has this feature and, if so, if it causes an alarm or zone bypass.  
TO ARM THE SYSTEM AND LEAVE  
Enter your user code.  
The System ARMED/ light will go on and the display will show:  
LCD Keypad:  
ON: AWAY  
Fixed-Word Keypad:  
ARM/ LED lit  
120  
LED Keypad:  
120s  
ARM/ LED lit  
NOTE: The number 120 shown above for the LCD and Fixed-Word keypads  
indicates a counter that is updated every second and displays the amount of time  
remaining to exit without sounding an alarm.  
Exit through a door designated by your installer as an exit/entry door. You must  
leave within the exit time programmed by your installer. Refer to the reference  
sheet for the time that has been set for your system.  
This system can be programmed by the installer for the AUTOSTAY feature, which  
automatically bypasses interior zones programmed for AUTOSTAY if you arm the  
system and do not exit through a delay zone during exit time.  
- 10 -  
 
Arming the System (cont)  
WHEN THE SYSTEM IS NOT READY  
If the system is not ready to be armed, the READY/  
light will be off and the  
display will show which zone or zones are not ready. The following conditions will  
be indicated by the zone lights (LED keypad) or described on the display:  
Fast Blink ...............................Alarm or tamper condition  
Slow Blink/Low Intensity ...Bypass  
Slow Pulse ..............................Trouble, problem with RF receiver, or low battery  
Solid On ...................................Zone faulted  
Example: If the READY/  
light is not lit and the Zone 1 light is solid on, an  
alarm sensor on Zone 1 is faulted. This might mean that a door is open or someone  
is walking in view of a motion sensor. Check all sensors on Zone 1 and resolve the  
problem. When all sensors are restored, the READY/  
light will come on and the  
zone light will go out. In this example, the display shows:  
NOT READY  
NOT RDY  
FRONT DOOR  
ZN 1  
and  
Determine which zone or zones are not ready, resolve the problem, and arm the  
system normally. If the problem cannot be resolved, you may bypass the zone that  
is not ready. Bypassing should only be done if the problem on the zone cannot be  
resolved, OR if you intentionally wish to leave the zone disarmed. For example, you  
would leave the zone disarmed if you plan to keep the window open for ventilation.  
Zones that are bypassed are not protected when the system is armed. See  
TO BYPASS A ZONE on page 13 for a description of the procedure.  
TO ARM THE SYSTEM AND STAY INSIDE  
To arm the perimeter portion of your burglar alarm and move around freely inside  
the premises, use the STAY mode.  
Check to make sure the system is ready. When it is ready, press:  
STAY  
/
followed by your user code.  
When the system has been armed successfully, the ARMED/ (STAY) light is lit  
and the following is displayed:  
LCD Keypad:  
Fixed-Word Keypad:  
LED Keypad:  
ON: STAY  
STAY/  
ARM/ and STAY/  
LEDs lit  
STAY  
REMEMBER: You must disarm the system or press  
/
to initiate  
the “quick exit” if you want to open the door or leave the premises after the exit  
time has expired. Quick Exit restarts the exit time without disarming the system.  
- 11 -  
 
Arming the System (cont)  
TO ARM THE SYSTEM IN INSTANT MODE  
In INSTANT mode, all alarm sensors, including doors that normally have a delay  
to allow you to disarm the system, will report an alarm immediately if activated.  
Check to make sure the system is READY/  
. When it is ready, press:  
INSTANT  
/
followed by your user code.  
When the system has been armed successfully, the ARM/  
light and the  
INSTANT/  
light are lit, and the following is displayed:  
LCD Keypad:  
ON: INSTANT  
Fixed-Word Keypad:  
INSTANT/  
LED Keypad:  
ARM/ and INSTANT/  
LED lit  
TO ARM THE SYSTEM IN INSTANT MODE AND STAY INSIDE  
In INSTANT STAY mode, the perimeter portion of your burglar alarm system is  
armed, but the time delays are eliminated from your normal entry/exit door(s). All  
interior protection is disarmed, so you are free to move around inside.  
Check to make sure the system is READY/  
. When it is ready, press:  
INSTANT  
/
STAY  
/
followed by your user code.  
When the system has been armed successfully, the ARM/  
light, the INSTANT /  
light, and the STAY/  
light are all lit, and the following is displayed:  
LCD Keypad:  
ON: STAY / INS  
Fixed-Word Keypad:  
LED Keypad:  
ARM/ , STAY/ , and  
INSTANT/ LEDs lit  
STAY/  
INSTANT/  
- 12 -  
 
Arming the System (cont)  
TO BYPASS A ZONE  
The Bypass function excludes a zone of protection from the security system until it  
is unbypassed (either by using the unbypass procedure or when you disarm the  
system). Bypassing can only be done while the system is disarmed.  
NOTE: 24-hour zones may be bypassed, but can only be unbypassed if the zone is  
not faulted (condition has been cleared).  
Press the BYPASS/  
button. Then enter your user code and the zone number  
to be bypassed, as follows:  
+ Zone  
No.  
followed by your user  
code†  
BYPASS  
/
If the Quick Bypass feature has been enabled by the installer, do not enter the  
user code when bypassing zones.  
NOTE: Bypassed zones are NOT protected when the system is armed. After the  
bypass command has been accepted, the keypad sounds one long beep, and the  
following is displayed:  
LCD Keypad:  
BYPASSED: ZN 01  
FRONT DOOR  
Fixed-Word Keypad:  
BYPASS/  
Zone number displayed  
LED Keypad:  
Zone LEDs of the zone(s)  
bypassed slowly blink  
To Bypass multiple zones, within 10 seconds of the BYPASS/  
Zone No. entry, enter:  
+ User Code +  
BYPASS  
/
+
Zone No.  
This command can be repeated for each zone to be bypassed.  
TO UNBYPASS A ZONE  
Pressing the BYPASS/  
button returns a bypassed zone to normal operation.  
To unbypass a zone, the system must be disarmed. (Also note that 24-hour zones  
cannot be unbypassed if they are faulted.) To unbypass a zone(s), repeat the bypass  
function as follows:  
+ Zone  
No.  
followed by your user  
code†  
BYPASS  
/
If the Quick Bypass feature has been enabled by the installer, do not enter the  
user code when unbypassing zones.  
After unbypassing, the zone display will show the state of the zones.  
- 13 -  
 
Disarming the System  
When you disarm the system, you disarm only the burglar portion of your system;  
any smoke or heat detectors and panic keys will remain armed. You must enter  
through a designated entry door and disarm the system within the time allowed.  
You can have different amounts of time for different entry points. See your system  
reference sheet (page 7) for the times established for your system.  
To disarm your system:  
Enter your user code.  
If no alarms have taken place, the ARMED/  
light will go off, or the display  
shows:  
LCD Keypad:  
SYSTEM READY  
Fixed-Glass Keypad:  
READY/ LED lit  
LED Keypad:  
READY/  
LED lit  
If alarms occurred when the system was armed or if a trouble condition exists, the  
display shows:  
LCD Keypad:  
ALM MEM  
Fixed-Glass Keypad:  
LED Keypad, zone LEDs:  
Fast Blink = alarm or tamper  
Slow Blink = bypass  
ZN1  
ARM LED/ lit  
Slow Pulse = trouble, problem  
with RF receiver, or low battery  
Solid On = zone faulted  
READY/  
LED blinks  
Burglary alarms will sound a steady tone at the keypad(s), and fire alarms will  
generate a pulsing sound.  
IMPORTANT: If an intrusion has taken place while you were away, do not enter  
until the location has been checked. Call for help from a neighbor's house and wait  
there for the police.  
To clear the display of alarm or trouble conditions and silence the audible alert:  
Enter your user code again.  
- 14 -  
 
User Codes  
TO ADD OR CHANGE A USER CODE  
Users can be added or changed directly at the keypad. Your system can have up to  
15 (OMNI400 and OMNI600), 32 (OMNI624), or 64 (OMNI848) different user codes,  
with each assigned to one of four authority levels and to a primary partition  
(OMNI624 and OMNI848 only). The authority level determines the functions that  
user can perform. In addition, your system can be set up for 4-digit or 6-digit user  
codes. Ask your installer which type of user codes is used in your system.  
To add or change a user code, press the following:  
CODE  
/
+
Master User Code  
User ID*  
New User Code  
Auth. Level  
nn  
[1-4]  
* Valid User ID numbers are 01–15 for the OMNI400 and OMNI600, 01–32 for the  
OMNI624, or 01–64 for the OMNI848.  
Authority Levels  
Level Functions Allowed  
1
Primary Master: access all partitions; can view log and set time; assign other user  
codes; all system functions  
2
Secondary Master: same as primary master except cannot change the primary  
masters code  
3
4
User: cannot assign codes and cannot bypass zones  
Limited user: same as level 3, except can disarm the system only if it was armed by  
another user with level 4 authority (cannot disarm if armed by user of higher authority  
level).  
ASSIGNING PARTITIONS TO USERS (OMNI624 and OMNI848 ONLY)  
When a user code is assigned, that user is automatically allowed to perform system  
functions in the partition in which the user’s code is assigned. You can also allow  
users to access other partitions and turn on open/close reporting to a pager by using  
the #7 command as follows:  
[master user code] [user no.] [1, 2, 3*, or 4]  
#
7
where: master user code = user with authority level 1 or 2  
user no. = the user that will be assigned access to other partitions  
1, 2, 3, or 4 = enter the partition(s) 1-3* you want this user to have access  
to; enter 4 if you want this user to send open/close reports to a pager  
* Partition 3 is available on the OMNI848 ONLY.  
- 15 -  
 
Miscellaneous Commands  
TO DELETE A USER CODE  
To delete a user, press the CODE/  
button followed by the 4-digit (or 6-digit)  
master user code. Enter the user number, then press [#] to delete. For example, to  
delete user 3, do the following:  
Master User Code  
User ID  
# to delete  
CODE  
/
03  
[#]  
NOTE: User no. 1, the master user, cannot be deleted but it can be changed using  
the ADD OR CHANGE A USER CODE procedure.  
DURESS  
Your system can be programmed to send an emergency signal to the central station  
if you are forced to enter the premises under threat. If you choose to include this  
feature, assign codes to user 15 (OMNI400 and OMNI600), 31 and 32 (OMNI624),  
or 60-64 (OMNI848), which are dedicated to this function, if programmed. Use  
these codes only under a duress circumstance.  
QUICK ARMING  
If programmed by your installer, Quick Arming allows you to arm the system in the  
AWAY mode without entering a user code.  
Press  
, then  
.
#
1
NOTES:  
Disarming your system always requires a valid user code.  
This system can be programmed by the installer for the AUTOSTAY feature  
which automatically bypasses interior zones if you arm the system and do not  
exit through a delay zone during exit time.  
QUICK FORCED ARMING  
If programmed by your installer, Quick Forced Arming allows you to arm the  
system in the AWAY mode by automatically bypassing all zones that are not ready.  
Press  
, then  
.
#
2
NOTES:  
A valid user code is still required to disarm the system.  
This system can be programmed by the installer for the AUTOSTAY feature  
which automatically bypasses interior zones programmed for AUTOSTAY if you  
arm the system and do not exit through a delay zone during exit time.  
UL NOTE: This feature is disabled on UL installations.  
- 16 -  
 
Miscellaneous Commands (cont)  
QUICK BYPASS  
If you have Quick Bypass programmed for your system, you can bypass zones  
without entering your user code. The Quick Bypass procedure is:  
BYPASS  
/
2-digit Zone No. (e.g., 01 for zone 1)  
NOTE: Bypassed zones are not protected when the system is armed. After the  
bypass command has been accepted, the keypad sounds one long beep. The zone  
light of the bypassed zone(s) slowly blinks, or the display shows:  
LCD Keypad:  
BYPASSED: ZN1  
Fixed-Word Keypad:  
BYPASS/ LED lit  
LED Keypad:  
Zone light of the bypassed  
zone(s) will slowly blink  
NOTE: Temporary users (e.g., babysitters, housekeepers, etc.) should not be shown  
the Bypass procedure.  
QUICK EXIT  
Quick Exit restarts the exit delay time if the system is already armed. This allows  
someone to leave after the system has been armed, without having to disarm the  
system first.  
STAY  
To restart the exit delay time, press:  
/
TURN CHIME ON/OFF  
Chime is an optional feature that causes the keypad to beep when selected doors  
are opened while the burglary protection is off or disarmed.  
Only your installer can program a zone for the Chime feature, but once  
programmed, you can turn Chime on or off to meet your daily needs.  
To turn Chime on or off: Press  
, then  
.
#
6
ASSIGN USERS ACCESS TO OTHER PARTITIONS (OMNI624 and OMNI848 ONLY)  
You can assign users access to any of the partitions in a multi-partition system by  
entering the following:  
[master code] [user number] [1, 2, 3*]  
#
7
where 1, 2, 3* are the partitions to which the user is authorized to access.  
* Partition 3 is available on the OMNI848 ONLY.  
- 17 -  
 
Miscellaneous Commands (cont)  
CHANGE PARTITION (OMNI624 and OMNI848 ONLY)  
To arm or disarm other partitions from your keypad, enter the following:  
[1-3, 0, 9]  
where: 1-3* = the desired partition you wish to change to  
When you enter a partition number (1-3*), the system displays the  
#
0
current armed state for that partition. You can then arm or disarm  
the partition by entering the arming/disarming command.  
= arms all partitions  
0
9
= disarms all partitions  
* Partition 3 is available on the OMNI848 ONLY.  
SET AUTO-ARM TIME  
Set Auto-Arm Time lets you set the time your system will automatically arm.  
To set the Auto On Time:  
Press  
+
+
+ user code + hour 00-23 + minute 00-59.  
#
5
4
The keypad will prompt you for the required entries.  
TO VIEW AUTOARM TIME  
To view the autoarm time for the partition to which the keypad is assigned, press:  
+
+
+ user code with authority level 1 or 2.  
#
5
2
AUTOARM TIME:  
05:00PM  
(The user code is not required if so programmed by installer.)  
DOOR STRIKE  
To activate door strikes:  
Press  
+
+
+ Door No.  
#
5
7
If programmed, certain user codes can also be used to open a door. See your installer  
for door numbers.  
- 18 -  
 
Miscellaneous Commands (cont)  
VIEW QUICK COMMAND LIST (LCD Keypads on OMNI624 and OMNI848 ONLY)  
To view a display of available quick commands, press:  
+
+
.
#
5
0
To step through the available quick commands, press  
.
#
To exit the quick command list, press  
.
VIEW TIME (LCD KEYPADS ONLY)  
To view the system time, press:  
as follows:  
+
+
. A typical display is  
#
5
1
Jan 27, 2001  
08:15A  
SET TIME  
To set the time, press:  
+
+ user code (not required if so  
#
3
programmed by installer), then follow the prompts (on LCD keypads only) and enter  
the hour, minute, month, day, and year. All entries are 2-digit entries. Additionally, if  
your system installer has set your system to use an internal crystal real-time clock,  
you will be promted to enter a crystal adjustment. If your clock has been keeping the  
proper time, respond to the crystal adjustment prompt by pressing  
followed  
1
by when the system prompts you for an adjustment value. If the  
0
0
clock has not been keeping time correctly, when the crystal adjustment prompt is  
displayed, proceed as follows:  
1. Enter 0 (Adjust down - Clock fast) or 1 (Adjust up - Clock slow). The adjustment  
value prompt is displayed.  
2. Determine how far off the clock is (in seconds) from the correct time.  
3. Determine the number of days since the last time the clock was set.  
4. Divide the number of seconds that the clock is off by the number of days since  
the last time the clock was set.  
5. Enter the result of step 4 as the adjust value. Valid entries are 00 for no change,  
1–29 for seconds to add (per day), or 1–30 for seconds to subtract (per day). If the  
value entered is valid, an acknowledgement is sounded. If the value entered is  
not within the valid range, an error is sounded.  
- 19 -  
 
Miscellaneous Commands (cont)  
DISPLAY ZONE DIRECTORY (LCD KEYPADS ONLY)  
To view a list of the zones in the current partition, press  
zones will automatically scroll.  
+
. The  
#
4
USER LOG VIEW (LCD KEYPADS ONLY)  
To view the system log, press:  
+
, +  
+ user code.*  
#
5
3
(*The user code is not required if so programmed by installer.)  
When the command is accepted, the display will show the most recent event.  
STAY  
Pressing either  
/
or  
exits this mode.  
Pressing any other key advances to the next valid log entry.  
KEY FOB LOW-BATTERY TEST (OMNI624 and OMNI848 ONLY)  
To activate the key fob low-battery test:  
Press :  
then  
+
#
5
6
The test mode is indicated as follows:  
LCD Keypad:  
Keyfob Bat. Test  
#56  
Fixed-Word Keypad:  
LED Keypad:  
An acknowledgement tone is  
sounded.  
AC  
=Exit  
FO  
TEST  
When a keyfob button is pressed, the system will provide a display indicating if the  
keyfob has a low-battery condition.  
The system exits this mode when the star  
key is pressed.  
KEYPAD BACKLIGHT TIMER  
If you are using an OMNI-KP, OMNI-KP-US, OMNI-LCD, or OMNI-LCD-US  
keypad, these keypads have a timer controlled keypad backlight that is on for 120-  
seconds following a key press (timer on) or constantly on (timer off).  
To change the backlight timer:  
CODE  
INSTANT  
OMNI-KP or OMNI-KP-US: Press the  
at the same time and hold down for two seconds until you hear a beep. Pressing the  
key toggles a zero or one in the display.  
/
and  
/
keys  
1
0 = Timer off (backlight always on)  
1 = Timer on (backlight on for 120-seconds following key press)  
Press the  
key to exit this Backlight menu.  
- 20 -  
 
Miscellaneous Commands (cont)  
INSTANT  
OMNI-LCD or OMNI-LCD-US: Press and hold down the  
/
and  
CODE  
/
keys at the same time for about two seconds. Press the  
1
key to toggle the display between:  
Backlight 120s time out …. and …. Backlight Always On  
Press the [] key to exit this Backlight menu.  
KEYPAD SOUNDER  
The sounder (or loudspeaker) housed inside the keypad emits (annunciates) sounds  
according to the condition of the security system. If you are using an OMNI-KP,  
OMNI-KP-US, OMNI-LCD, or OMNI-LCD-US keypad, the sounds from the keypad  
sounder can be controlled.  
To change the keypad sounder:  
BYPASS  
CODE  
OMNI-KP or OMNI-KP-US: Press the  
/
and  
/
keys  
at the same time and hold down for two seconds until you hear a beep. Press any  
key (except the  
0 = Sounder off  
key) to toggle the sounder on or off.  
1 = Sounder on  
Press the [] key to exit the sounder menu.  
OMNI-LCD or OMNI-LCD-US: There are four modes available in the Sounder Menu.  
They are as follows:  
On – Normal Sounder Keys (all sounds on)  
Key – Only Key Clicks  
Fire – Only Fire Sounder (temporal sounder – not supported by all systems)  
Off – No Sounds at all  
To use the OMNI-LCD or OMNI-LCD-US sounder menu:  
BYPASS  
CODE  
1. Press the  
/
and  
/
keys at the same time and  
hold down for two seconds. This accesses the Sounder Menu.  
2. Press the  
desired mode).  
3. Press the  
appears on the display).  
4. Press the key to adjust the sound of the key acknowledge (Ack H or L  
appears on the display).  
5. Press the key to exit the Sounder Menu.  
key to toggle through the four modes listed above (stop at  
1
key to toggle through the sounder volume choices (high or low  
2
3
- 21 -  
 
Using a Pager  
If so programmed, the system can send messages to a pager. The messages are  
displayed as follows:  
ACCT E XXX  
where:  
"ACCT" = the 4-digit central station No. 1 account number set by your system  
installer. We suggest that you obtain the number from your system  
installer and record it here. "ACCT" =  
"E" = the event code. There are 4 event types: alarms, troubles, openings, and  
closings. These event codes are as follows:  
Openings = 0, Closings = 1, Alarm or Trouble = 9  
"XXX" = the zone* or user* designation, depending on the event.  
* Possible Zone numbers are: 001–008 (OMNI400), 001–012 (OMNI600),  
001–024 (OMNI624), 001–048 (OMNI848)  
Possible User numbers are: 001–015 (OMNI400 and OMNI600), 001–032  
(OMNI624), 001–064 (OMNI848)  
Note that the following actions not requiring a user code are reported as:  
Soft keys *&#, 1&3, and 7&9 send event number 9 and zone number of 124.  
If the system is programmed by your installer for Stay Arms Stay, when the  
system is armed by pressing the [STAY/ ] key it will be reported to the pager as  
user 001.  
If the system is programmed by your installer for Instant Arms Away, when the  
system is armed by pressing the [INSTANT/  
] key it will be reported to the  
pager as user 001.  
If the system is armed with a keyswitch, programmable digits that were set up by  
your installer will be sent to the pager as the user number.  
When the system auto arms, it will be reported to the pager as user number 126.  
If multiple events occur, only the signal for the highest-priority event is sent. Events ranked from  
highest to lowest priority are alarm, trouble, open, and close.  
CHANGING THE PAGER PHONE NUMBER (FOLLOW-ME)  
You can change your pager follow-me phone number as follows if your installer  
enabled this feature:  
1. Access pager number programming by pressing the following keys in sequence:  
,
, and  
.
#
5
8
An acknowledgement tone sounds to indicate pager number programming has  
been accessed.  
- 22 -  
 
Using a Pager (cont)  
The [#], [5], [8] command is accessible only while the system is disarmed and the dialer, dialer  
delay, and bell are not active.  
In pager phone number programming mode, only the LCD keypad provides visual display of the  
numbers already programmed or numbers that are being changed. The LED and fixed-word  
style keypads provide no visual keypad display of these numbers.  
2. Enter your new pager phone number. Your new pager phone number may  
consist of up to 16 characters (1-9, 0). It may be necessary to add time to allow  
the pager to answer before dialing your pager number. To enter a 2-second  
CODE  
pause, press the  
/
key. (Entering a 2-second pause is optional  
and is not required to enter your pager phone number.) If the CODE/  
was pressed, it counts as one character. The keypad will emit a single  
acknowledgement chirp as each number is pressed.  
key  
3. Press the  
key after you have made your pager phone number changes.  
#
Pressing the [#] key saves your new pager number and nulls out the remaining  
locations. An acknowledgement tone sounds.  
To exit without saving changes, press the  
key to exit pager phone number  
programming. An acknowledgement tone sounds to indicate pager number  
programming has been exited.  
If you press the [] key without first pressing the [#] key to save your new pager phone number,  
the system exits the pager phone number programming mode without saving the changes.  
If no key is pressed within 10 seconds, the pager phone number programming mode times out  
and exits automatically without saving any information entered.  
TURN PAGER REPORTING ON/OFF FOR THE PARTITION (OMNI624 and 848 ONLY)  
You can turn on/off the open-close reporting feature for a partition by pressing  
,
. The display prompts you to toggle the feature on/off with the  
#
#
8
key. To exit, press the key.  
TURN PAGER REPORTING ON/OFF FOR A USER  
You can turn on/off the open-close reporting feature for a user by entering the  
following :  
,
, [master code] [user number] [4]  
#
7
NOTE: The [#], [7] command is also used to assign a user to a different partition for  
the OMNI624 and 848 only (see ASSIGNING PARTITIONS TO USERS on page 15).  
- 23 -  
 
Testing the System  
SYSTEM TEST  
It is recommended that you test your system once a week using the  
following procedure:  
NOTE: If your system is monitored, contact your central station before you perform  
this test.  
1. Arm your security system.  
2. Wait until your exit time is over. Then activate the system by opening a protected  
zone (for example: a window or door).  
3. Confirm that the alarm sounding device (bell or siren) sounds. If your system is  
connected to a central station, the keypad will sound the ringback tone to confirm  
that the signal was received.  
4. Disarm the security system.  
5. Call the central station to tell them you are finished testing.  
BATTERY TEST  
It is recommended that you test your battery once a month. In order to test your  
backup/standby battery, the following procedure should be followed:  
1. Disconnect AC Power from the system.  
2. Observe that the AC indicator light on the keypad goes off.  
3. Activate your alarm by performing the above SYSTEM TEST. Remember to  
contact your central station if your system is monitored.  
4. Reconnect AC Power to the system.  
IMPORTANT: Use only batteries recommended by your installer as a replacement.  
The National Fire Protection Association publishes a standard for fire warning  
equipment (NFPA publication #72). Further information can be obtained by  
contacting: NFPA Public Affairs Dept., Batterymarch Park, Quincy, MA 02269.  
If you have any further questions about the operation of your system, please contact  
your alarm company.  
- 24 -  
 
Recommendations On Smoke Detectors  
With regard to the number and placement of smoke/heat detectors, we subscribe to  
the recommendations contained in the National Fire Protection Association’s (NFPA)  
Standard #72 noted below.  
Early warning fire detection is best achieved by the installation of fire detection  
equipment in all rooms and areas of the household as follows: A smoke detector  
installed outside of each separate sleeping area, in the immediate vicinity of the  
bedrooms and on each additional story of the family living unit, including basements  
and excluding crawl spaces and unfinished attics.  
In addition, the NFPA recommends that you install heat or smoke detectors in the  
living room, dining room, bedroom(s), kitchen, hallway(s), attic, furnace room, utility  
and storage rooms, basements, and attached garages.  
KITCHEN  
KITCHEN  
LIVING ROOM  
BDRM  
BDRM  
DINING  
BEDROOM  
BEDROOM  
TV ROOM  
DINING  
BEDROOM  
BEDROOM  
LIVING ROOM  
Smoke Detectors for Minimum Protection  
Smoke Detectors for Additional Protection  
Heat-Activated Detectors  
BEDROOM  
TO  
BR  
BEDROOM  
BEDROOM  
KTCHN  
GARAGE  
CLOSED  
DOOR  
LVNG RM  
.
BASEMENT  
floor_plan-V0  
- 25 -  
 
Emergency Evacuation  
Establish and regularly practice a plan of escape in the  
event of fire. The following steps are recommended by the  
National Fire Protection Association:  
1. Position your detector or your interior and/or exterior  
sounders so that they can be heard by all occupants.  
OOM  
BEDR  
CLOSET  
2. Determine two means of escape from each room. One  
path of escape should lead to the door that permits  
normal exit from the building. The other is an  
alternative route, such as through a window, should your  
normal escape path be unpassable. Station an escape  
ladder at such windows if there is a long drop to the  
ground.  
H
T
OOM  
BEDR  
OOM  
BEDR  
BA  
2nd FLOOR  
OOM  
BEDR  
KITCHEN  
BACK DOOR  
3. Sketch a floor plan of the building. Show windows,  
doors, stairs, and rooftops that can be used to escape.  
Indicate escape routes for each room. Keep these routes  
free from obstruction and post copies of the escape routes  
in every room.  
H
OOM  
BEDR  
T
BA  
1st FLOOR  
4. Assure that all bedroom doors are shut while you are  
asleep. This will prevent deadly smoke from entering  
while you escape.  
5. Try the door. If the door is hot, check your alternate  
escape route. If the door is cool, open it cautiously. Be  
prepared to slam the door shut if smoke or heat rushes  
in.  
BACK  
6. When smoke is present, crawl on the ground. Do not  
walk upright, since smoke rises and may overcome you.  
Clearer air is near the floor.  
7. Escape quickly; don’t panic.  
FRONT  
8. Establish a common meeting place outdoors, away from  
your house, where everyone can meet and then take  
steps to contact the authorities and account for those  
missing. Choose someone to assure that nobody returns  
to the house — many die going back.  
floor_plan2-V0  
- 26 -  
 
Glossary  
AC/  
:
Small green power on-off light between the center buttons on the keypad. When lit, the  
system is running on primary power; when not lit, the system is running off the backup battery.  
ALARM: Sound from keypad or other horn/siren indicates a burglar alarm, fire alarm, or other  
condition you should be alerted to.  
ARMED/DISARMED: These terms refer to the burglary portion of your security system. There are  
several levels of operation that allow you to protect part of your premises while you remain inside.  
Fire sensors and other emergency and environmental features are always active and ready (armed);  
they are not affected in any way by arming or disarming the burglary portion of your security  
system. See ARMED-INSTANT, ARMED-STAY, and STAY.  
ARM-STAY:  
A system setting that turns on the perimeter protection of the building but allows  
movement throughout the interior.  
ARMED INDICATOR: Red light in the upper portion of the keypad labeled "Armed/ ." When lit, some  
part of the burglar alarm system is armed; when not lit, the burglary portion of the system is  
disarmed.  
AWAY: A system setting that protects the premises while it is unoccupied. All burglary sensors are  
active.  
BURGLARY/FIRE: The two major functions of a security system. Fire protection is always armed and  
cannot be disarmed. The burglary sensors protect against unauthorized entry into your premises.  
The burglary protection can be armed and disarmed, and programmed for special levels of access  
and notification.  
BYPASS FEATURE: The Bypass feature allows you to exclude a selected zone or zones from the  
burglar alarm protection.  
BYPASS/  
BUTTON: A button on the keypad used to activate the Bypass feature.  
CENTRAL STATION: The signal monitoring center contacted by your security system over the  
telephone and/or other communication channels when alarms are activated, if your system is  
programmed to communicate alarms off site. The central station will follow their procedures and  
your instructions for contacting the proper authorities when a signal is received.  
CHIME FEATURE: An optional feature that causes the keypad to chime for one second when selected  
doors are opened when the burglary protection is disarmed. Once programmed by your installer,  
you can turn Chime on and off with [#] [6].  
DISARMED: See ARMED/DISARMED.  
DURESS: Duress is a system feature that you may have programmed into your system. If someone  
forces you to disarm your system, entering the special Duress user code disarms the system and  
sends a silent duress emergency signal to the central station so personnel there can respond  
appropriately.  
ENTRY DELAY: The period of time allowed between opening a designated entry/exit door and  
disarming the alarm system before the system registers an alarm condition. This is determined at  
the time of installation. Your system supports two entry times, allowing you to have a different  
length of time for different doors.  
- 27 -  
 
Glossary (cont)  
EXIT DELAY: The period of time allowed between arming the system and leaving through a designated  
exit/entry door before the system will register an alarm condition. This is determined at the time of  
installation.  
INTERIOR ZONE: An interior zone is a group of points that protect the interior of your premises. You  
may want to arm the perimeter portion of your system while leaving the interior zones disarmed to  
allow you to open interior doors and pass interior motion detectors without causing an alarm.  
KEYPAD: A keypad is your link into your system. It displays alarm and trouble messages, shows  
faulted zones, and allows you to arm/disarm the system using the buttons. Your system will have  
one or more keypads.  
PANIC BUTTON: A push button that allows you to signal the central station that you need immediate  
assistance. Your system has programmable Keypad Send Help Alerts that can also serve as Panic  
buttons.  
PERIMETER ZONE: A perimeter zone is a group of points that protect the exterior of your premises.  
Your outside doors and windows would be programmed as a perimeter zone.  
SENSOR: The actual alarm sensor, detector or device installed to detect an intrusion, fire, or  
environmental problem. Examples include: door contacts, window contacts, motion sensors,  
glassbreak sensors, smoke detectors, rate-of-rise heat detectors, temperature sensors, flood/water  
sensors, and carbon monoxide gas detectors.  
SILENT CONDITION: Most types of alarms and troubles alert you with the keypad sounder and the  
sirens, horns, or speakers located in your premises. The intent is to advise you of the alarm or  
trouble and allow you to respond promptly. The audible sounds also let an intruder know that he  
has been detected and will hopefully scare him away. In some circumstances, an audible alarm  
might put your life in danger. For that reason, those alarms are programmed as silent conditions.  
For an example, see DURESS.  
SYSTEM: Your security system is composed of three main parts: 1) the control panel, which functions  
as the system brain and the link to the monitoring agency (central station); 2) the keypad(s), which  
provide you with system status and allow you to input commands; 3) security sensors such as door  
and window contacts, motion sensors, smoke detectors, and other sensors as required to detect  
intrusion, fire, and other conditions for your premises.  
USER CODE: A user code is a 4- or 6-digit code that is required to operate the system. The OMNI400  
and OMNI600 supports up to 15 separate user codes, the OMNI624 supports up to 32 separate user  
codes, and the OMNI848 supports up to 64 separate user codes. The system supports one master  
user who can add/delete other user codes. Two of the user codes may be dedicated to special  
functions as defined by your alarm company at the time of installation. (See the User Code  
Assignments in this manual.)  
ZONE: A zone is a collection of sensors with common characteristics grouped together for your  
operating convenience.  
- 28 -  
 
RADIO FREQUENCY EMISSIONS STATEMENTS  
FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 15  
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This  
device may not cause harmful interference, and (2) this device must accept any interference received, including  
interference that may cause undesired operation.  
INDUSTRY CANADA  
This Class B digital apparatus complies with Canadian ICES-003.  
Cet Appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.  
TELEPHONE/MODEM INTERFACE STATEMENTS  
FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 68  
This equipment complies with Part 68 of the FCC rules. On the front cover of this equipment is a label that contains  
the FCC registration number and Ringer Equivalence Number (REN). You must provide this information to the  
telephone company when requested.  
This equipment uses the following USOC jack: RJ31X  
This equipment may not be used on telephone-company-provided coin service. Connection to party lines is subject  
to state tariffs. This equipment is hearing-aid compatible.  
INDUSTRY CANADA  
NOTICE: The Industry Canada Label identifies certified equipment. This certification means that the equipment  
meets telecommunications network protective, operational and safety requirements as prescribed in the appropriate  
Terminal Equipment Technical Requirements document(s). The Department does not guarantee the equipment will  
operate to the users satisfaction.  
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local  
telecommunications company. The equipment must also be installed using an acceptable method of connection. The  
customer should be aware that compliance with the above conditions may not prevent degradation of service in  
some situations.  
Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any repairs or  
alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications  
company to request the user to disconnect the equipment.  
Users should ensure for their own protection that the electrical ground connections of the power utility, telephone  
lines and internal metallic water pipe system, if present, are connected together, This precaution may be particularly  
important in rural areas.  
Caution: Users should not attempt to make such connections themselves but should contact appropriate electric  
inspection authority, or electrician, as appropriate.  
RINGER EQUIVALENCE NUMBER NOTICE  
The Ringer Equivalence Number (REN) assigned to each terminal device provides an indication of the maximum  
number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist  
of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all  
the devices does not exceed 5.  
- 29 -  
 
INDUSTRIE CANADA  
AVIS: L’étiquette dIndustrie Canada identifie le matériel homologué. Cette étiquette certifie que le matériel est  
conforme aux normes de protection, dexploitation et de sécurité des réseaux de télécommunications, comme le  
prescrivent les documents concernant les exigences techniques relatives au matériel terminal. Le Ministère nassure  
toutefois pas que le matériel fonctionnera à la satisfaction de lutilisateur.  
Avant dinstaller ce matériel, lutilisateur doit sassurer quil est permis de le raccorder aux installations de lenterprise  
locale de télécommunication. Le matériel doit également être installé en suivant une méthode acceptée da  
raccordement. Labonné ne doit pas oublier quil est possible que la conformité aux conditions énoncées ci-dessus  
nempêche pas la dégradation du service dans certaines situations.  
Les réparations de matériel nomologué doivent être coordonnées par un représentant désigné par le fournisseur.  
Lentreprise de télécommunications peut demander à lutilisateur da débrancher un appareil à la suite de réparations  
ou de modifications effectuées par lutilisateur ou à cause de mauvais fonctionnement.  
Pour sa propre protection, lutilisateur doit sassurer que tous les fils de mise à la terre de la source denergie  
électrique, de lignes téléphoniques et des canalisations deau métalliques, sil y en a, sont raccordés ensemble.  
Cette précaution est particulièrement importante dans les régions rurales.  
Avertissement: Lutilisateur ne doit pas tenter de faire ces raccordements lui-même; il doit avoir racours à un  
service dinspection des installations électriques, ou à un électricien, selon le cas.  
AVIS: L’indice d’équivalence de la sonnerie (IES) assigné à chaque dispositif terminal indique le nombre maximal  
de terminaux qui peuvent être raccordés à une interface. La terminaison dune interface téléphonique peut consister  
en une combinaison de quelques dispositifs, à la seule condition que la somme dindices d’équivalence de la  
sonnerie de tous les dispositifs nexcède pas 5.  
TELEPHONE OPERATIONAL PROBLEMS  
In the event of telephone operational problems, disconnect the control by removing the plug from the RJ31X wall  
jack. We recommend that your certified installer demonstrate disconnecting the phones on installation of the system.  
Do not disconnect the phone connection inside the control/communicator. Doing so will result in the loss of your  
phone lines. If the regular phone works correctly after the control/communicator has been disconnected from the  
phone lines, the control/communicator has a problem and should be returned for repair. If upon disconnection of the  
control/communicator, there is still a problem on the line, notify the telephone company that it has a problem and  
request prompt repair service. The user may not under any circumstances (in or out of warranty) attempt any service  
or repairs to the system. It must be returned to the factory or an authorized service agency for all repairs.  
This control unit was manufactured under rigid quality standards and complies with all UL requirements for  
its intended use. Maintenance is best performed by your installing company with trained service personnel.  
0560 DECLARATION OF CONFORMITY  
Application of Council Directives 98/482/EC, 89/336/EEC, 73/23/EEC  
Standards to which conformity is declared:  
ETS 300 001:1997  
EN50081-1  
EN 50130-4:1995  
EN 60950:1998  
Intended use:  
Restrictions:  
Alarm system, analogue subscriber interface to PSTN  
None  
EMC environment: RESIDENTIAL, COMMERCIAL AND LIGHT INDUSTRY  
Manufacturer:  
Address:  
Honeywell International Inc.  
165 Eileen Way, Syosset NY 11791, USA  
Customer support: Contact your local distributor  
- 30 -  
 
Limitations of This Alarm System  
While this system is an advanced design security system, it does not offer guaranteed protection against burglary, fire, or  
other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a  
variety of reasons. For example:  
Intruders may gain access through unprotected openings or have the technical sophistication to bypass an alarm  
sensor or disconnect an alarm warning device.  
Intrusion detectors (e.g., passive infrared detectors), smoke detectors, and many other sensing devices will not work  
without batteries, or if the batteries are not put in properly. Devices powered solely by AC will not work if their AC power  
supply is cut off for any reason, however briefly.  
Signals sent by wireless transmitters may be blocked or reflected by metal before they reach the alarm receiver. Even if  
the signal path has been recently checked during a weekly test, blockage can occur if a metal object is moved into the  
path.  
A user may not be able to reach a panic or emergency button quickly enough.  
While smoke detectors have played a key role in reducing residential fire deaths, they may not activate or provide early  
warning for a variety of reasons in as many as 35% of all fires. Some of the reasons smoke detectors used in  
conjunction with the System may not work are as follows: Smoke detectors may not sense fires that start where smoke  
cannot reach the detectors, such as in chimneys, in walls, or roofs, or on the other side of closed doors. Smoke  
detectors also may not sense a fire on another level of a residence or building. A second-floor detector, for example,  
may not sense a first-floor or basement fire. Moreover, smoke detectors have sensing limitations. No smoke detector  
can sense every kind of fire every time. In general, detectors may not always warn about fires caused by carelessness  
and safety hazards like smoking in bed, violent explosions, escaping gas, improper storage of flammable materials,  
overloaded electrical circuits, children playing with matches, or arson. Depending on the nature of the fire and/or the  
location of the smoke detectors, the detector, even if it operates as anticipated, may not provide sufficient warning to  
allow all occupants to escape in time to prevent injury or death.  
Passive Infrared Motion Detectors can detect intrusion only within the designed ranges as diagrammed in their  
Installation Manual. Passive Infrared Detectors do not provide volumetric area protection. They do create multiple  
beams of protection, and intrusion can only be detected in unobstructed areas covered by the beams. They cannot  
detect motion or intrusion that takes place behind walls, ceilings, floors, closed doors, glass partitions, glass doors or  
windows. Mechanical tampering, masking, painting or spraying, of any material on the mirrors, windows or any part of  
the optical system can reduce their detection ability. Passive Infrared Detectors sense changes in temperature;  
however, as the ambient temperature of the protected area approaches the temperature range of 90º to 104º  
Fahrenheit (32º to 40º Celsius), the detection performance can decrease.  
Alarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers who are located on the  
other side of closed or partly open doors. If warning devices sound on a different level of the residence from the  
bedrooms, then they are less likely to waken or alert people inside the bedrooms. Even persons who are awake may  
not hear the warning if the alarm is muffled by noise from a stereo, radio, air conditioner, other appliances, or by  
passing traffic. Finally, alarm warning devices, however loud, may not warn hearing-impaired people or waken deep  
sleepers.  
Telephone lines needed to transmit alarm signals from a premises to a central monitoring station may be out of service  
or temporarily out of service. Telephone lines are also subject to compromise by sophisticated intruders.  
However, even if the system responds to the emergency as intended, occupants may have insufficient time to protect  
themselves from the emergency situation. In the case of a monitored alarm system, authorities may not respond  
appropriately.  
This equipment, like other electrical devices, is subject to component failure. Even though this equipment is designed  
to last as long as 20 years, the electronic components could fail at any time.  
The most common cause of an alarm system not functioning when an intrusion or fire occurs is inadequate maintenance.  
This alarm system should be tested weekly to make sure all sensors are working properly.  
Installing an alarm system may make one eligible for lower insurance rates, but an alarm system is not a substitute for  
insurance. Homeowners, property owners and renters should continue to act prudently in protecting themselves and  
continue to insure their lives and property.  
We continue to develop new and improved protection devices. Users of alarm systems owe it to themselves and their  
loved ones to learn about these developments.  
- 31 -  
 
ONE YEAR LIMITED WARRANTY  
Honeywell International Inc., acting through its Security & Custom Electronics business ("Seller"), 165 Eileen  
Way, Syosset, New York 11791, warrants its security equipment (the "product") to be free from defects in  
materials and workmanship for one year from date of original purchase, under normal use and service. Seller's  
obligation is limited to repairing or replacing, at its option, free of charge for parts, labor, or transportation, any  
product proven to be defective in materials or workmanship under normal use and service. Seller shall have no  
obligation under this warranty or otherwise if the product is altered or improperly repaired or serviced by  
anyone other than the Seller. In case of defect, contact the security professional who installed and maintains  
your security equipment or the Seller for product repair.  
This one year Limited Warranty is in lieu of all other express warranties, obligations or liabilities. THERE ARE  
NO EXPRESS WARRANTIES, WHICH EXTEND BEYOND THE FACE HEREOF. ANY IMPLIED  
WARRANTIES, OBLIGATIONS OR LIABILITIES MADE BY SELLER IN CONNECTION WITH THIS  
PRODUCT, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, OR FITNESS FOR A  
PARTICULAR PURPOSE OR OTHERWISE, ARE LIMITED IN DURATION TO A PERIOD OF ONE YEAR  
FROM THE DATE OF ORIGINAL PURCHASE. ANY ACTION FOR BREACH OF ANY WARRANTY, IN-  
CLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY, MUST BE  
BROUGHT WITHIN 12 MONTHS FROM DATE OF ORIGINAL PURCHASE. IN NO CASE SHALL SELLER  
BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF  
THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY  
WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER'S OWN NEGLIGENCE  
OR FAULT. Some states do not allow limitation on how long an implied warranty lasts or the exclusion or  
limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.  
Seller does not represent that the product may not be compromised or circumvented; that the product will  
prevent any personal injury or property loss by burglary, robbery, fire or otherwise; or that the product will in all  
cases provide adequate warning or protection. Buyer understands that a properly installed and maintained  
alarm may only reduce the risk of a burglary, robbery, fire or other events occurring without providing an alarm,  
but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property  
loss as a result. CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY,  
PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARN-  
ING. HOWEVER, IF SELLER IS HELD LIABLE, WHETHER DIRECTLY OR INDIRECTLY, FOR ANY LOSS  
OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE, REGARDLESS OF CAUSE  
OR ORIGIN, SELLER'S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE  
OF THE PRODUCT, WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER.  
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.  
No increase or alteration, written or verbal, to this warranty is authorized.  
165 Eileen Way, Syosset, New York 11791  
Copyright © 2004 Honeywell International Inc.  
ÊN9939V54Š  
N9939V5 4/04 Rev. A  
 

Graco Inc Pressure Washer 308 505 User Manual
Haier Washer Dryer HWM60 113S User Manual
Hans Grohe Plumbing Product 41528XX0 User Manual
Honeywell Air Cleaner F111 Series 3 User Manual
Honeywell Furnace 62 2030 01 User Manual
Honeywell Thermostat CT87A User Manual
Hotpoint Washer VVSR1070 User Manual
HP Hewlett Packard Computer Keyboard 510678 001 User Manual
Humminbird Fish Finder 586C HD User Manual
Husqvarna Snow Blower 12524SB User Manual